summaryrefslogtreecommitdiffstats
path: root/target/linux/ar71xx/base-files/etc
diff options
context:
space:
mode:
Diffstat (limited to 'target/linux/ar71xx/base-files/etc')
-rw-r--r--target/linux/ar71xx/base-files/etc/defconfig/wndr3700v2/network69
-rw-r--r--target/linux/ar71xx/base-files/etc/defconfig/wndr3800/network69
-rwxr-xr-xtarget/linux/ar71xx/base-files/etc/diag.sh2
-rwxr-xr-xtarget/linux/ar71xx/base-files/etc/uci-defaults/leds4
4 files changed, 2 insertions, 142 deletions
diff --git a/target/linux/ar71xx/base-files/etc/defconfig/wndr3700v2/network b/target/linux/ar71xx/base-files/etc/defconfig/wndr3700v2/network
deleted file mode 100644
index 69d7dc712..000000000
--- a/target/linux/ar71xx/base-files/etc/defconfig/wndr3700v2/network
+++ /dev/null
@@ -1,69 +0,0 @@
-config interface loopback
- option ifname lo
- option proto static
- option ipaddr 127.0.0.1
- option netmask 255.0.0.0
-
-config interface lan
- option ifname eth0.1
- option type bridge
- option proto static
- option ipaddr 192.168.1.1
- option netmask 255.255.255.0
-
-config interface wan
- option ifname eth1
- option proto dhcp
-
-config switch
- option name rtl8366s
- option reset 1
- option enable_vlan 1
- # Blinkrate: 0=43ms; 1=84ms; 2=120ms; 3=170ms; 4=340ms; 5=670ms
- option blinkrate 2
-
-config switch_vlan
- option device rtl8366s
- option vlan 1
- option ports "0 1 2 3 5t"
-
-config switch_port
- # Port 1 controls the GREEN configuration of LEDs for
- # the switch and the section does not correspond to a real
- # switch port.
- #
- # 0=LED off; 1=Collision/FDX; 2=Link/activity; 3=1000 Mb/s;
- # 4=100 Mb/s; 5=10 Mb/s; 6=1000 Mb/s+activity; 7=100 Mb/s+activity;
- # 8=10 Mb/s+activity; 9=10/100 Mb/s+activity; 10: Fiber;
- # 11: Fault; 12: Link/activity(tx); 13: Link/activity(rx);
- # 14: Link (master); 15: separate register
-
- option device rtl8366s
- option port 1
- option led 6
-
-config switch_port
- # Port 2 controls the ORANGE configuration of LEDs for
- # the switch and the section does not correspond to a real
- # switch port.
- #
- # See the key above for switch port 1 for the meaning of the
- # 'led' setting below.
-
- option device rtl8366s
- option port 2
- option led 9
-
-config switch_port
- # Port 5 controls the configuration of the WAN LED and the
- # section does not correspond to a real switch port.
- #
- # To toggle the use of green or orange LEDs for the WAN port,
- # see the LED setting for wndr3700:green:wan in /etc/config/system.
- #
- # See the key above for switch port 1 for the meaning of the
- # 'led' setting below.
-
- option device rtl8366s
- option port 5
- option led 2
diff --git a/target/linux/ar71xx/base-files/etc/defconfig/wndr3800/network b/target/linux/ar71xx/base-files/etc/defconfig/wndr3800/network
deleted file mode 100644
index 69d7dc712..000000000
--- a/target/linux/ar71xx/base-files/etc/defconfig/wndr3800/network
+++ /dev/null
@@ -1,69 +0,0 @@
-config interface loopback
- option ifname lo
- option proto static
- option ipaddr 127.0.0.1
- option netmask 255.0.0.0
-
-config interface lan
- option ifname eth0.1
- option type bridge
- option proto static
- option ipaddr 192.168.1.1
- option netmask 255.255.255.0
-
-config interface wan
- option ifname eth1
- option proto dhcp
-
-config switch
- option name rtl8366s
- option reset 1
- option enable_vlan 1
- # Blinkrate: 0=43ms; 1=84ms; 2=120ms; 3=170ms; 4=340ms; 5=670ms
- option blinkrate 2
-
-config switch_vlan
- option device rtl8366s
- option vlan 1
- option ports "0 1 2 3 5t"
-
-config switch_port
- # Port 1 controls the GREEN configuration of LEDs for
- # the switch and the section does not correspond to a real
- # switch port.
- #
- # 0=LED off; 1=Collision/FDX; 2=Link/activity; 3=1000 Mb/s;
- # 4=100 Mb/s; 5=10 Mb/s; 6=1000 Mb/s+activity; 7=100 Mb/s+activity;
- # 8=10 Mb/s+activity; 9=10/100 Mb/s+activity; 10: Fiber;
- # 11: Fault; 12: Link/activity(tx); 13: Link/activity(rx);
- # 14: Link (master); 15: separate register
-
- option device rtl8366s
- option port 1
- option led 6
-
-config switch_port
- # Port 2 controls the ORANGE configuration of LEDs for
- # the switch and the section does not correspond to a real
- # switch port.
- #
- # See the key above for switch port 1 for the meaning of the
- # 'led' setting below.
-
- option device rtl8366s
- option port 2
- option led 9
-
-config switch_port
- # Port 5 controls the configuration of the WAN LED and the
- # section does not correspond to a real switch port.
- #
- # To toggle the use of green or orange LEDs for the WAN port,
- # see the LED setting for wndr3700:green:wan in /etc/config/system.
- #
- # See the key above for switch port 1 for the meaning of the
- # 'led' setting below.
-
- option device rtl8366s
- option port 5
- option led 2
diff --git a/target/linux/ar71xx/base-files/etc/diag.sh b/target/linux/ar71xx/base-files/etc/diag.sh
index cb3b85177..3af66b7e3 100755
--- a/target/linux/ar71xx/base-files/etc/diag.sh
+++ b/target/linux/ar71xx/base-files/etc/diag.sh
@@ -111,7 +111,7 @@ get_status_led() {
wzr-hp-g300nh)
status_led="buffalo:green:router"
;;
- wndr3700 | wndr3700v2 | wndr3800)
+ wndr3700)
status_led="wndr3700:green:power"
;;
wnr2000)
diff --git a/target/linux/ar71xx/base-files/etc/uci-defaults/leds b/target/linux/ar71xx/base-files/etc/uci-defaults/leds
index 0a724221c..a0779effd 100755
--- a/target/linux/ar71xx/base-files/etc/uci-defaults/leds
+++ b/target/linux/ar71xx/base-files/etc/uci-defaults/leds
@@ -123,9 +123,7 @@ wrt160nl)
set_led_wlan "wlan" "WLAN" "wrt160nl:blue:wlan" "phy0tpt"
;;
-wndr3700 | \
-wndr3700v2 | \
-wndr3800)
+wndr3700)
set_led_default "wan" "WAN LED (green)" "wndr3700:green:wan" "0"
set_led_usbdev "usb" "USB" "wndr3700:green:usb" "1-1"
;;